3M™ Cold Shrink QT-II Silicone Rubber Termination Kit 5613A, Non-Shielded, 5 kV and 8 kV, 3/0 AWG-300 kcmil, 3/kit
Main PictureDownload

3M™ Cold Shrink QT-II Silicone Rubber Termination Kit 5613A, Non-Shielded, 5 kV and 8 kV, 3/0 AWG-300 kcmil, 3/kit

3M™ Cold Shrink QT-II Silicone Rubber Termination Kit 5613A, Non-Shielded, 5 kV and 8 kV, 3/0 AWG-300 kcmil, 3/kit

  • 3M ID7000132471
    SAP ID7000132471
    Legacy SKU80610592885
    Part Number5613A
    Product Number5613A
    Local Catalog Identifier5613A
    Base SKUB5005111045
    Keywords3M, Cold Shrink, QT-II Outdoor Termination Kits, 5610 A Series, silicone rubber insulation, medium voltage cables, unshielded power cables, indoor applications, outdoor applications, electrical construction, energy markets, data centers, track resistant, hydrophobic property, long lasting service life, leakage currents, weather exposed, termination kits, single conductor terminations, non-skirted terminations, pliable tight seal, connection lug, power cable termination.
    Brand3M™
    Global Product HierarchyPower Cable Terminations
    Commodity2320 - Cable Acc,CS and L&M
    Extended Intended Use Disclaimer3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.
    Intended Use DisclaimerFor industrial/occupational use only. Not for consumer sale or use.
  • Base (B) - Article Number00054007495512
    Unit of Use (1) - Article Number00054007495512
    Shipper (6) - Article Number50054007495517
  • Marketplace Formal Name3M™ Cold Shrink QT-II Silicone Rubber Termination Kit 5613A, Non-Shielded, 5 kV and 8 kV, 3/0 AWG-300 kcmil, 3/kit
    Material Description5613A SILICONE RUBBER COLD SHRINK
    Marketplace Description3M™ Cold Shrink QT II 5610 A Series Termination Kit includes 3 non skirted, single conductor terminations. It ensures a pliable, tight seal for unshielded power cables. The silicone rubber insulation allows the termination to withstand voltages of 5kV to 8 kV.
    Marketplace Description Extended3M™ Cold Shrink QT II 5610 A Series Termination Kit is designed for terminating medium voltage cables in both indoor and weather exposed outdoor applications. The track resistant, silicone rubber insulation of the termination has a hydrophobic property and offers a long lasting service life while minimizing leakage currents in wet conditions.
    Bullets
    • Includes 3 non-skirted, single-conductor, cold shrink terminations
    • Provides a seal between the connecting lug and unshielded power cables
    • Silicone rubber insulation offers durability and reduces leakage currents in damp conditions
    • Suitable for indoor and outdoor applications
    • Withstands voltages of 5kV to 8 kV
  • ApplicationCable Termination
  • Breakout BootNo
  • Cable ShieldingNon-shielded
  • Conductor Sizes (Imperial)
    • 250 kcmil
    • 3/0 AWG
    • 4/0 AWG
    • 300 kcmil
  • Indoor/OutdoorIndoor Non-skirted
  • Insulation Outer Diameter (Imperial)
    • 0.56 in
    • 0.57 in
    • 0.58 in
    • 0.59 in
    • 0.6 in
    • 0.61 in
    • 0.62 in
    • 0.63 in
    • 0.64 in
    • 0.65 in
    • 0.66 in
    • 0.67 in
    • 0.68 in
    • 0.69 in
    • 0.7 in
    • 0.71 in
    • 0.72 in
    • 0.73 in
    • 0.74 in
    • 0.75 in
    • 0.76 in
    • 0.77 in
    • 0.78 in
    • 0.79 in
    • 0.8 in
    • 0.81 in
    • 0.82 in
    • 0.83 in
    • 0.84 in
    • 0.85 in
    • 0.86 in
    • 0.87 in
    • 0.88 in
    • 0.89 in
    • 0.9 in
    • 0.91 in
    • 0.92 in
    • 0.93 in
    • 0.94 in
    • 0.95 in
    • 0.96 in
    • 0.97 in
    • 0.98 in
    • 0.99 in
    • 1 in
    • 1.01 in
    • 1.02 in
    • 1.03 in
    • 1.04 in
    • 1.05 in
    • 1.06 in
    • 1.07 in
    • 1.08 in
    • 1.09 in
    • 1.1 in
    • 1.11 in
    • 1.12 in
    • 1.13 in
    • 1.14 in
    • 1.15 in
    • 1.16 in
    • 1.17 in
    • 1.18 in
    Insulation Outer Diameter (Metric)
    • 14.224 mm
    • 14.478 mm
    • 14.732 mm
    • 14.986 mm
    • 15.24 mm
    • 15.494 mm
    • 15.748 mm
    • 16.002 mm
    • 16.256 mm
    • 16.51 mm
    • 16.764 mm
    • 17.018 mm
    • 17.272 mm
    • 17.526 mm
    • 17.78 mm
    • 18.034 mm
    • 18.288 mm
    • 18.542 mm
    • 18.796 mm
    • 19.05 mm
    • 19.304 mm
    • 19.558 mm
    • 19.812 mm
    • 20.066 mm
    • 20.32 mm
    • 20.574 mm
    • 20.828 mm
    • 21.082 mm
    • 21.336 mm
    • 21.59 mm
    • 21.844 mm
    • 22.098 mm
    • 22.352 mm
    • 22.606 mm
    • 22.86 mm
    • 23.114 mm
    • 23.368 mm
    • 23.622 mm
    • 23.876 mm
    • 24.13 mm
    • 24.384 mm
    • 24.638 mm
    • 24.892 mm
    • 25.146 mm
    • 25.4 mm
    • 25.654 mm
    • 25.908 mm
    • 26.162 mm
    • 26.416 mm
    • 26.67 mm
    • 26.924 mm
    • 27.178 mm
    • 27.432 mm
    • 27.686 mm
    • 27.94 mm
    • 28.194 mm
    • 28.448 mm
    • 28.702 mm
    • 28.956 mm
    • 29.21 mm
    • 29.464 mm
    • 29.718 mm
    • 29.972 mm
    Insulation RejacketingNo
  • MaterialSilicone Rubber
    Maximum Conductor Size (Imperial)300 kcmil
    Maximum Conductor Size (Metric)150 mm²
  • Minimum Conductor Size (Imperial)3/0 AWG
    Minimum Conductor Size (Metric)95 mm²
  • Number of Conductors1
  • Product Series5610A
  • Voltage
    • 8 kV
    • 5 kV
  • Sales unitKIT
    SAP Shelf Life In Days36
    Target Warehouse Location Lead Time60
    SAP External Material Group39120000
  • Base (B) - Billing UnitKIT
    Base (B) - Customary Cubic Dimension209.16062 IN3
    Base (B) - Customary Gross Weight0.95016 LB
    Base (B) - Customary Net Weight0.71612 LB
    Base (B) - Metric Net Weight0.324772 KG
    Base (B) - Metric Cubic Dimension3427.515 CCM
    Base (B) - Item Quantity1
    Base (B) - UnitKIT
  • Consumer (2) - Item Quantity0
  • Inner (3) - Item Quantity0
  • Shipper (6) - Billing UnitKIT
    Shipper (6) - Customary Cubic Dimension209.16062 IN3
    Shipper (6) - Customary Gross Weight0.95016 LB
    Shipper (6) - Customary Net Weight0.71612 LB
    Shipper (6) - Customary Height Dimension3.58268 IN
    Shipper (6) - Customary Length Dimension10.98425 IN
    Shipper (6) - Customary Width Dimension5.31496 IN
    Shipper (6) - Metric Weight0.430912 KG
    Shipper (6) - Metric Net Weight0.324772 KG
    Shipper (6) - Metric Cubic Dimension3427.515 CCM
    Shipper (6) - Metric Height Dimension9.1 CM
    Shipper (6) - Metric Length Dimension27.9 CM
    Shipper (6) - Metric Width Dimension13.5 CM
    Shipper (6) - Item Quantity1
    Shipper (6) - UnitCS
  • Pallet (8) - Billing UnitKIT
    Pallet (8) - Customary Cubic Dimension91596.99762 IN3
    Pallet (8) - Customary Gross Weight743.085 LB
    Pallet (8) - Customary Net Weight220.56615 LB
    Pallet (8) - Customary Height Dimension45.27559 IN
    Pallet (8) - Customary Length Dimension48.0315 IN
    Pallet (8) - Customary Width Dimension42.12598 IN
    Pallet (8) - Metric Weight337.0 KG
    Pallet (8) - Metric Net Weight100.03 KG
    Pallet (8) - Metric Cubic Dimension1501000.0 CCM
    Pallet (8) - Metric Height Dimension115.0 CM
    Pallet (8) - Metric Length Dimension122.0 CM
    Pallet (8) - Metric Width Dimension107.0 CM
    Pallet (8) - Item Quantity308
    Pallet (8) - UnitPAL