3M™ Cold Shrink Quick Insulator QI 18/57-325, 1 kV, 10/Case
Main PictureDownload

3M™ Cold Shrink Quick Insulator QI 18/57-325, 1 kV, 10/Case

3M™ Cold Shrink Quick Insulator QI 18/57-325, 1 kV, 10/Case

  • 3M ID7000133178
    SAP ID7000133178
    Legacy SKU80611443518
    Part NumberQI-18/57-325
    Local Catalog IdentifierQI-18/57-325
    Base SKUB00019994
    KeywordsCold Shrink, EPDM rubber insulating sleeve, Cold Shrink rubber insulating sleeve, Cold Shrink Quick Insulators QI Series, Cold Shrink Insulators QI Series, Quick Insulators QI Series, 3M Cold Shrink Insulator, Rubber Insulation, QI Series, Built-in mastic in electrical insulator, electrical insulation range taking
    Brand3M™
    Global Product HierarchyCold Shrink Tubing
    Commodity2320 - Cable Acc,CS and L&M
    Extended Intended Use Disclaimer3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.
    Intended Use DisclaimerFor industrial/occupational use only. Not for consumer sale or use.
  • Base (B) - Article Number00051128577516
    Unit of Use (1) - Article Number00051128577516
    Shipper (6) - Article Number50051128577511
  • Marketplace Formal Name3M™ Cold Shrink Quick Insulator QI 18/57-325, 1 kV, 10/Case
    Material DescriptionQI-18/57-325 COLD SHRINK INSULATOR
    Marketplace Description3M™ Cold Shrink Quick Insulator QI Series consists of open-ended and factory-expanded tubular rubber sleeves that feature sealing mastic on each end loaded on a removable plastic core. To install the connection, position it over the inline connector, pull the loose tab on the plastic core while unwinding the core in a counterclockwise direction, allowing the ends of the tube to shrink and form a secure seal. The core and tube sizing, combined with sealing mastic at each end, allow for a broader application range while preserving the seal and insulation properties of the EPDM rubber tube. Designed for primary insulation of solid dielectric insulated wires and cable splices rated up to 1000 volts, the insulators allow for direct burial or submersible applications. They are easy to install by hand, requiring no additional tools or heating sources. Accommodating a variety of cable sizes, 3M™ Cold Shrink Quick Insulator QI Series provides reliable thermal stability, high chemical resistance, and a water-resistant seal that meets the standard for ANSI C-119.1. These insulators are ideal for dig-in and sheath repairs, inline conductor transition connectors, and secondary splices for both copper and aluminum conductors, withstanding an operating temperature range between -40 °F to 194 °F (-40 °C to 90 °C). When you need dependable insulating properties with long-lasting resiliency and pressure performance, 3M™ Cold Shrink Quick Insulator QI Series is your go-to solution.
    Marketplace Description Extended3M has over 40 years of lab-tested and industry-proven results demonstrating the reliability of cold shrink technology. 3M™ Cold Shrink Quick Insulator QI Series and the other products in the cold shrink family are engineered with specially formulated materials that deliver a durable environmental seal and insulation. Five diameter sizes accommodate cables up to 1000 volts, ranging from 8 AWG to 3000 kcmil, for both copper and aluminum conductors with crimped connectors. For applications with high UV exposure or where visual inspection isn't feasible, it is recommended to overwrap the tubing with Scotch® Super 33+™ Vinyl Electrical Tape or Scotch® Self-Fusing Silicone Rubber Electrical Tape 70.
    Bullets
    • BUILT STRONG: Made of EPDM rubber, enduring operating temperatures ranging from -40 °F to 194 °F (-40 °C to 90 °C)
    • DESIGNED TO PERFORM: Offers reliable primary insulation for solid dielectric wires and secondary splices rated up to 1000 volts
    • EASY TO INSTALL: Requires no tools or heating sources and can be installed by hand
    • HIGH-RESISTANCE: Provides excellent wet electrical properties and resists water, acids, and alkalis
    • LONG-LASTING: Maintains thermal stability, resiliency, and pressure for dependable performance
    • MULTIPURPOSE: For dig-in and sheath repairs, inline conductor transition connectors, and secondary splices for both copper and aluminum conductors
    • WATER-RESISTANT SEAL: Meets the water-resistant requirements of ANSI C-119.1
    • WORK YOUR WAY: Accommodates a variety of cable sizes that can be used in direct burial or submersible applications
  • Application
    • Insulation, mechanical protection, repair
    • Cable Connection
  • Cable ShieldingNon-shielded
    Cable TypePower Cable
  • Conductor Material
    • Copper
    • Aluminum
    Conductor Sizes (Imperial)
    • 800 kcmil
    • 250 kcmil
    • 750 kcmil
    • 500 kcmil
    • 1000 kcmil
    • 350 kcmil
    • 300 kcmil
    • 650 kcmil
    • 1250 kcmil
    • 600 kcmil
    • 900 kcmil
    • 400 kcmil
    • 700 kcmil
  • Indoor/OutdoorBoth
    Inner Diameter After Shrink (Imperial)0.71 in
  • Inner Diameter After Shrink (Metric)18 mm
    Inner Diameter Before Shrink (Imperial)2.25 in
    Inner Diameter Before Shrink (Metric)57.2 mm
  • MaterialEPDM Rubber
    Maximum Conductor Size (Imperial)400 kcmil
    Maximum Conductor Size (Metric)185 mm²
    Maximum Operating Temperature (Celsius)90 °C
    Maximum Operating Temperature (Fahrenheit)194 °F
  • Minimum Conductor Size (Imperial)
    • 250 kcmil (Copper)
    • 250 kcmil (Aluminum)
    Minimum Conductor Size (Metric)
    • 120 mm² (Copper)
    • 120 mm² (Aluminum)
    Minimum Operating Temperature (Celsius)-40 °C
    Minimum Operating Temperature (Fahrenheit)-40 °F
    ModelCold-shrink
  • Number of Conductors1
  • Product ColorBlack
    Product TypeSplice
  • Splice TypeCold Shrink
  • Voltage1 kV
  • Sales unitEA
    SAP Shelf Life In Days60
    Target Warehouse Location Lead Time60
    SAP External Material Group31270000
  • Base (B) - Billing UnitEA
    Base (B) - Customary Cubic Dimension233.28091 IN3
    Base (B) - Customary Gross Weight0.94016 LB
    Base (B) - Customary Net Weight0.93999 LB
    Base (B) - Customary Height Dimension3.9 IN
    Base (B) - Customary Length Dimension15.95 IN
    Base (B) - Customary Width Dimension3.75197 IN
    Base (B) - Metric Net Weight0.4263 KG
    Base (B) - Metric Cubic Dimension3822.77429 CCM
    Base (B) - Metric Height Dimension9.906 CM
    Base (B) - Metric Length Dimension40.513 CM
    Base (B) - Metric Width Dimension9.53 CM
    Base (B) - Item Quantity1
    Base (B) - UnitEA
  • Consumer (2) - Item Quantity0
  • Inner (3) - Item Quantity0
  • Shipper (6) - Billing UnitEA
    Shipper (6) - Customary Cubic Dimension3148.65442 IN3
    Shipper (6) - Customary Gross Weight10.89491 LB
    Shipper (6) - Customary Net Weight9.39992 LB
    Shipper (6) - Customary Height Dimension12.79528 IN
    Shipper (6) - Customary Length Dimension17.3622 IN
    Shipper (6) - Customary Width Dimension14.17323 IN
    Shipper (6) - Metric Weight4.941 KG
    Shipper (6) - Metric Net Weight4.263 KG
    Shipper (6) - Metric Cubic Dimension51597.0 CCM
    Shipper (6) - Metric Height Dimension32.5 CM
    Shipper (6) - Metric Length Dimension44.1 CM
    Shipper (6) - Metric Width Dimension36.0 CM
    Shipper (6) - Item Quantity10
    Shipper (6) - UnitCS
  • Pallet (8) - Billing UnitEA
    Pallet (8) - Customary Cubic Dimension85311.52743 IN3
    Pallet (8) - Customary Gross Weight262.395 LB
    Pallet (8) - Customary Net Weight197.39822 LB
    Pallet (8) - Customary Height Dimension42.91339 IN
    Pallet (8) - Customary Length Dimension47.6378 IN
    Pallet (8) - Customary Width Dimension41.73228 IN
    Pallet (8) - Metric Weight119.0 KG
    Pallet (8) - Metric Net Weight89.523 KG
    Pallet (8) - Metric Cubic Dimension1398000.0 CCM
    Pallet (8) - Metric Height Dimension109.0 CM
    Pallet (8) - Metric Length Dimension121.0 CM
    Pallet (8) - Metric Width Dimension106.0 CM
    Pallet (8) - Item Quantity210
    Pallet (8) - UnitPAL