3M™ Cold Shrink QT-II Indoor Termination Kit 5625K, 15 kV, 1.09"-1.80" (27,2-45,7mm) Cable Insul. O.D., 3 Terms/Kit, 1 Kits/Case
Main PictureDownload

3M™ Cold Shrink QT-II Indoor Termination Kit 5625K, 15 kV, 1.09"-1.80" (27,2-45,7mm) Cable Insul. O.D., 3 Terms/Kit, 1 Kits/Case

3M™ Cold Shrink QT-II Indoor Termination Kit 5625K, 15 kV, 1.09"-1.80" (27,2-45,7mm) Cable Insul. O.D., 3 Terms/Kit, 1 Kits/Case

  • 3M ID7100041431
    SAP ID7100041431
    Legacy SKU80611612187
    Part Number5625K
    Local Catalog Identifier5625K
    Base SKUB5005111048
    Keywords3M, Cold Shrink Termination Kit, QT-II Termination Kit, 3M Cold Shrink, Medium Voltage Termination, Electric Field Stress Management, Silicone Rubber Insulation, Track Resistant Insulation, Hydrophobic Silicone, IEEE Standard 48, Class 1 Termination, Indoor Termination Kit, Weather Protected Termination, Skirted Terminations, Power Cable Termination, Tape Shield Termination, Wire Shield Termination, UniShield Termination, UV Stable Insulator, High Dielectric Constant Material, Constant Radial Pressure, Living Seal, Leakage Current Minimization, Medium Voltage Power Cables, Electrical Termination.
    Brand3M™
    Global Product HierarchyPower Cable Terminations
    Commodity2320 - Cable Acc,CS and L&M
    Extended Intended Use Disclaimer3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use.  Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice.  Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage.  For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert.
    Intended Use DisclaimerFor industrial/occupational use only. Not for consumer sale or use.
  • Base (B) - Article Number00051128608937
    Unit of Use (1) - Article Number00051128608937
    Shipper (6) - Article Number50051128608932
  • Marketplace Formal Name3M™ Cold Shrink QT-II Indoor Termination Kit 5625K, 15 kV, 1.09"-1.80" (27,2-45,7mm) Cable Insul. O.D., 3 Terms/Kit, 1 Kits/Case
    Material Description5625K QTII INDOOR TERMINATION 3 Pts/Kit
    Marketplace Description3M™ Cold Shrink QT II 5620K & 5630K Series Termination Kit includes sufficient material to make 3, skirted terminations. Each kit has materials to make 3 single phase terminations for tape shield, wire shield and UniShield® power cables..
    Marketplace Description Extended3M™ Cold Shrink QT II 5620K & 5630K Series Termination Kits are designed for terminating solid dielectric shielded, medium voltage power cables. The QT II termination uses high dielectric constant (High K) stress control tube insulated with a UV stable, track resistant, silicone insulator. The track resistant, hydrophobic propertities of the silicone rubber minimize leakage currents. Meets the requirements of IEEE Standard 48, for Class 1 for outdoor, weather exposed environments.
    Bullets
    • 110 kV BIL; Voltage rating per class of termination family: 5/8 kV:95 kV BIL, 15 kV
    • Comes with sufficient materials to make 3 terminations
    • High dielectric-constant material manages the distribution of electric field stress
    • Meets IEEE Standard 48, Class 1 for weather-protected applications
    • One-piece cold shrink termination.
    • Silicone cold shrink application provides constant radial pressure, "living seal"
    • Silicone rubber insulation is track-resistance and hydrophobic action
    • Suitable for weather protected areas (indoor)
  • ApplicationCable Termination
  • Breakout BootNo
  • Cable Shielding
    • Tape Shield
    • Wire Shield
    • UniShield®
  • Conductor Sizes (Imperial)
    • 800 kcmil
    • 750 kcmil
    • 500 kcmil
    • 1000 kcmil
    • 350 kcmil
    • 600 kcmil
    • 900 kcmil
    • 400 kcmil
    • 700 kcmil
  • Insulation Outer Diameter (Imperial)
    • 1.09 in
    • 1.1 in
    • 1.11 in
    • 1.12 in
    • 1.13 in
    • 1.14 in
    • 1.15 in
    • 1.16 in
    • 1.17 in
    • 1.18 in
    • 1.19 in
    • 1.2 in
    • 1.21 in
    • 1.22 in
    • 1.23 in
    • 1.24 in
    • 1.25 in
    • 1.26 in
    • 1.27 in
    • 1.28 in
    • 1.29 in
    • 1.3 in
    • 1.31 in
    • 1.32 in
    • 1.33 in
    • 1.34 in
    • 1.35 in
    • 1.36 in
    • 1.37 in
    • 1.38 in
    • 1.39 in
    • 1.4 in
    • 1.41 in
    • 1.42 in
    • 1.43 in
    • 1.44 in
    • 1.45 in
    • 1.46 in
    • 1.47 in
    • 1.48 in
    • 1.49 in
    • 1.5 in
    • 1.51 in
    • 1.52 in
    • 1.53 in
    • 1.54 in
    • 1.55 in
    • 1.56 in
    • 1.57 in
    • 1.58 in
    • 1.59 in
    • 1.6 in
    • 1.61 in
    • 1.62 in
    • 1.63 in
    • 1.64 in
    • 1.65 in
    • 1.66 in
    • 1.67 in
    • 1.68 in
    • 1.69 in
    • 1.7 in
    • 1.71 in
    • 1.72 in
    • 1.73 in
    • 1.74 in
    • 1.75 in
    • 1.76 in
    • 1.77 in
    • 1.78 in
    • 1.79 in
    • 1.8 in
    Insulation Outer Diameter (Metric)
    • 27.686 mm
    • 27.94 mm
    • 28.194 mm
    • 28.448 mm
    • 28.702 mm
    • 28.956 mm
    • 29.21 mm
    • 29.464 mm
    • 29.718 mm
    • 29.972 mm
    • 30.226 mm
    • 30.48 mm
    • 30.734 mm
    • 30.988 mm
    • 31.242 mm
    • 31.496 mm
    • 31.75 mm
    • 32.004 mm
    • 32.258 mm
    • 32.512 mm
    • 32.766 mm
    • 33.02 mm
    • 33.274 mm
    • 33.528 mm
    • 33.782 mm
    • 34.036 mm
    • 34.29 mm
    • 34.544 mm
    • 34.798 mm
    • 35.052 mm
    • 35.306 mm
    • 35.56 mm
    • 35.814 mm
    • 36.068 mm
    • 36.322 mm
    • 36.576 mm
    • 36.83 mm
    • 37.084 mm
    • 37.338 mm
    • 37.592 mm
    • 37.846 mm
    • 38.1 mm
    • 38.354 mm
    • 38.608 mm
    • 38.862 mm
    • 39.116 mm
    • 39.37 mm
    • 39.624 mm
    • 39.878 mm
    • 40.132 mm
    • 40.386 mm
    • 40.64 mm
    • 40.894 mm
    • 41.148 mm
    • 41.402 mm
    • 41.656 mm
    • 41.91 mm
    • 42.164 mm
    • 42.418 mm
    • 42.672 mm
    • 42.926 mm
    • 43.18 mm
    • 43.434 mm
    • 43.688 mm
    • 43.942 mm
    • 44.196 mm
    • 44.45 mm
    • 44.704 mm
    • 44.958 mm
    • 45.212 mm
    • 45.466 mm
    • 45.72 mm
  • Number of Conductors1
    Number of Skirts-12345
  • Suitable for High VoltageNo
  • Voltage
    • 8 kV
    • 15 kV
    • 5 kV
  • ECCNEAR99
    Harmonized Tariff Schedule Nbr8546900000
    Sales unitKIT
    SAP Shelf Life In Days36
    Target Warehouse Location Lead Time60
    SAP External Material Group39120000
  • Base (B) - Billing UnitKIT
    Base (B) - Customary Cubic Dimension156.89235 IN3
    Base (B) - Customary Gross Weight3.13551 LB
    Base (B) - Customary Net Weight3.05834 LB
    Base (B) - Customary Height Dimension1.5 IN
    Base (B) - Customary Length Dimension15.5 IN
    Base (B) - Customary Width Dimension6.74803 IN
    Base (B) - Metric Net Weight1.387 KG
    Base (B) - Metric Cubic Dimension2570.995 CCM
    Base (B) - Metric Height Dimension3.81 CM
    Base (B) - Metric Length Dimension39.37 CM
    Base (B) - Metric Width Dimension17.14 CM
    Base (B) - Previous Packaging Level Quantity0.00
    Base (B) - Item Quantity1
    Base (B) - Total Unit Quantity0.00
    Base (B) - UnitKIT
    Base (B) - Pallet Layer Quantity7.00
    Base (B) - Shipping Container Per Layer Quantity15
  • Consumer (2) - Item Quantity0
  • Inner (3) - Item Quantity0
  • Shipper (6) - Billing UnitKIT
    Shipper (6) - Customary Cubic Dimension712.89827 IN3
    Shipper (6) - Customary Gross Weight3.63825 LB
    Shipper (6) - Customary Net Weight3.05834 LB
    Shipper (6) - Customary Height Dimension5.98425 IN
    Shipper (6) - Customary Length Dimension16.1811 IN
    Shipper (6) - Customary Width Dimension7.3622 IN
    Shipper (6) - Metric Weight1.65 KG
    Shipper (6) - Metric Net Weight1.387 KG
    Shipper (6) - Metric Cubic Dimension11682.264 CCM
    Shipper (6) - Metric Height Dimension15.2 CM
    Shipper (6) - Metric Length Dimension41.1 CM
    Shipper (6) - Metric Width Dimension18.7 CM
    Shipper (6) - Previous Packaging Level Quantity1.00
    Shipper (6) - Previous Packaging Level UnitKIT
    Shipper (6) - Item Quantity1
    Shipper (6) - Total Unit Quantity1.00
    Shipper (6) - Item UnitKIT
    Shipper (6) - UnitCS
  • Pallet (8) - Billing UnitKIT
    Pallet (8) - Customary Cubic Dimension93122.59718 IN3
    Pallet (8) - Customary Gross Weight416.745 LB
    Pallet (8) - Customary Net Weight321.12518 LB
    Pallet (8) - Customary Height Dimension46.85039 IN
    Pallet (8) - Customary Length Dimension47.6378 IN
    Pallet (8) - Customary Width Dimension41.73228 IN
    Pallet (8) - Metric Weight189.0 KG
    Pallet (8) - Metric Net Weight145.635 KG
    Pallet (8) - Metric Cubic Dimension1526000.0 CCM
    Pallet (8) - Metric Height Dimension119.0 CM
    Pallet (8) - Metric Length Dimension121.0 CM
    Pallet (8) - Metric Width Dimension106.0 CM
    Pallet (8) - Previous Packaging Level Quantity105.00
    Pallet (8) - Previous Packaging Level UnitBOX
    Pallet (8) - Item Quantity105
    Pallet (8) - Total Unit Quantity105.00
    Pallet (8) - Item UnitKIT
    Pallet (8) - UnitPAL
    Pallet (8) - Pallet Layer Quantity7.00
    Pallet (8) - Shipping Container Per Layer Quantity15