3M™ Cold Shrink Insulator 8428-12, Tape/Wire/UniShield® Shielding, 1 kV, Standard, 10/Case
3M™ Cold Shrink Insulator 8428-12, Tape/Wire/UniShield® Shielding, 1 kV, Standard, 10/Case
3M ID 7100164760 SAP ID 7100164760 Legacy SKU 80611203508 Part Number 8428-12M Local Catalog Identifier 8428-12M Base SKU B5005063011 Keywords Cold Shrink, Connector Insulators 8420, Connector Insulators 8430, Cold Shrink 8420, Cold Shrink 8430, Cold Shrink Connector Insulators, Insulation Connector 8420, Insulation Connector 8430, 3m cold shrink, Insulation connector, 8420 series, 8430 series Brand 3M™ Global Product Hierarchy Cold Shrink Tubing Commodity 2320 - Cable Acc,CS and L&M Extended Intended Use Disclaimer 3M industrial and occupational products are intended, labeled, and packaged for sale to trained industrial and occupational customers for workplace use. Unless specifically stated otherwise on the applicable product packaging or literature, these products are not intended, labeled, or packaged for sale to or use by consumers (e.g., for home, personal, primary or secondary school, recreational/sporting, or other uses not described in the applicable product packaging or literature), and must be selected and used in compliance with applicable health and safety regulations and standards (e.g., U.S. OSHA, ANSI), as well as all product literature, user instructions, warnings, and other limitations, and the user must take any action required under any recall, field action, or other product use notice. Misuse of 3M industrial and occupational products may result in injury, sickness, death, or property damage. For help with product selection and use, consult your on-site safety professional, industrial hygienist, or other subject matter expert. Intended Use Disclaimer For industrial/occupational use only. Not for consumer sale or use. Base (B) - Article Number 00054007437468 Unit of Use (1) - Article Number 00054007437468 Shipper (6) - Article Number 50054007437463 Marketplace Formal Name 3M™ Cold Shrink Insulator 8428-12, Tape/Wire/UniShield® Shielding, 1 kV, Standard, 10/Case Material Description 8428-12M COLD SHRINK INSULATOR Marketplace Description 3M™ Cold Shrink Connector Insulators 8420 and 8430 Series are EPDM, factory-expanded rubber tubes designed with cold shrink technology and loaded on a removable plastic core. To install the connection, position it over the inline connector, pull the loose tab on the plastic core while unwinding the core in a counterclockwise direction, allowing the ends of the tube to shrink and form a secure seal. Engineered for primary insulation of solid dielectric insulated wires and cable splices rated up to 1000 volts, the insulators can be used for indoor and outdoor applications to provide a water-resistant seal. They are easy to install by hand, requiring no additional tools or heating sources. Accommodating a variety of cable sizes, 3M™ Cold Shrink Connector Insulators 8420 and 8430 Series provide physical protection and environmental sealing for terminal lug barrels, conduit coupling, and conduit-to-cable breakouts. These insulators are ideal for direct burial or submersible applications involving communication and other non-electrical operations, such as dig-in and sheath repairs, and secondary splices for both copper and aluminum conductors. They can withstand an operating temperature range between -40 °F to 194 °F (-40 °C to 90 °C) and meet the water seal requirements of ANSI C119.1. When you need dependable insulating properties with long-lasting resiliency, look no further than 3M™ Cold Shrink Connector Insulators 8420 and 8430 Series. Marketplace Description Extended 3M has over 40 years of lab-tested and industry-proven results demonstrating the reliability of cold shrink technology. 3M™ Cold Shrink Connector Insulators 8420 and 8430 Series and the other products in the cold shrink family are engineered with specially formulated materials that deliver a durable environmental seal and insulation. The core and tube sizing allows for a broader application range while preserving the seal and insulation properties of the EPDM rubber tube. Six diameter sizes accommodate cables up to 1000 volts, ranging from 10 AWG to 1000 kcmil, for both copper and aluminum conductors. For applications with high UV exposure or where visual inspection isn't feasible, it is recommended to overwrap the tubing with Scotch® Super 33+™ Vinyl Electrical Tape or Scotch® Self-Fusing Silicone Rubber Electrical Tape 70. Bullets - BUILT STRONG: Made of EPDM rubber, enduring operating temperatures ranging from -40 °F to 194 °F (-40 °C to 90 °C)
- DESIGNED TO PERFORM: Offers reliable primary insulation for solid dielectric wires and secondary splices rated up to 1000 volts
- EASY TO INSTALL: Requires no tools or heating sources and can be installed by hand
- HIGH-RESISTANCE: Provides excellent wet electrical properties and resists fluid splashes, acids, and alkalis
- LONG-LASTING: Maintains thermal stability, resiliency, and pressure for dependable performance
- MULTIPURPOSE: For environmental sealing on terminal lug barrels, conduit coupling, conduit-to-cable breakouts, and more
- WATER-RESISTANT SEAL: Meets the water-resistant requirements of ANSI C-119.1
- WORK YOUR WAY: Accommodates a variety of cable sizes that can be used in direct burial or submersible applications
Application Insulation, mechanical protection, repair Breaking Strength (Imperial) 26.3 Kilogram_Per_Centimetre Cable Shielding - Non-shielded
- Tape Shield
- Wire Shield
- UniShield®
Cable Type Power Cable Conductor Material - Copper
- Aluminum
Conductor Sizes (Imperial) - 800 kcmil
- 750 kcmil
- 500 kcmil
- 650 kcmil
- 600 kcmil
- 700 kcmil
Indoor/Outdoor Both Inner Diameter After Shrink (Imperial) 0.949 in Inner Diameter After Shrink (Metric) 24.1 mm Inner Diameter Before Shrink (Imperial) 1.937 in Inner Diameter Before Shrink (Metric) 49.2 mm Material EPDM Rubber Maximum Conductor Size (Imperial) 800 kcmil Maximum Conductor Size (Metric) 400 mm² Maximum Operating Temperature (Celsius) 90 °C Maximum Operating Temperature (Fahrenheit) 194 °F Minimum Conductor Size (Imperial) 600 kcmil Minimum Conductor Size (Metric) 300 mm² Minimum Operating Temperature (Celsius) -40 °C Minimum Operating Temperature (Fahrenheit) -40 °F Model Cold-shrink Number of Conductors 1 Product Color Black Product Type Splice Splice Type Cold Shrink Voltage 1 kV ECCN EAR99 Harmonized Tariff Schedule Nbr 8546900000 Sales unit EA SAP Shelf Life In Days 60 Target Warehouse Location Lead Time 60 SAP External Material Group 39120000 Base (B) - Billing Unit EA Base (B) - Customary Cubic Dimension 105.84225 IN3 Base (B) - Customary Gross Weight 0.5781 LB Base (B) - Customary Net Weight 0.05151 LB Base (B) - Metric Net Weight 0.02336 KG Base (B) - Metric Cubic Dimension 1734.437 CCM Base (B) - Previous Packaging Level Quantity 0.00 Base (B) - Item Quantity 1 Base (B) - Total Unit Quantity 0.00 Base (B) - Unit EA Base (B) - Pallet Layer Quantity 7.00 Base (B) - Shipping Container Per Layer Quantity 9 Consumer (2) - Item Quantity 0 Inner (3) - Item Quantity 0 Shipper (6) - Billing Unit EA Shipper (6) - Customary Cubic Dimension 1058.42253 IN3 Shipper (6) - Customary Gross Weight 5.78099 LB Shipper (6) - Customary Net Weight 0.51509 LB Shipper (6) - Customary Height Dimension 5.75 IN Shipper (6) - Customary Length Dimension 14.8748 IN Shipper (6) - Customary Width Dimension 12.3748 IN Shipper (6) - Metric Weight 2.621763 KG Shipper (6) - Metric Net Weight 0.2336 KG Shipper (6) - Metric Cubic Dimension 17344.37 CCM Shipper (6) - Metric Height Dimension 14.605 CM Shipper (6) - Metric Length Dimension 37.782 CM Shipper (6) - Metric Width Dimension 31.432 CM Shipper (6) - Previous Packaging Level Quantity 10.00 Shipper (6) - Previous Packaging Level Unit EACH Shipper (6) - Item Quantity 10 Shipper (6) - Total Unit Quantity 10.00 Shipper (6) - Item Unit EACH Shipper (6) - Unit CS Pallet (8) - Billing Unit EA Pallet (8) - Customary Cubic Dimension 90982.27662 IN3 Pallet (8) - Customary Gross Weight 410.06826 LB Pallet (8) - Customary Net Weight 32.45099 LB Pallet (8) - Customary Height Dimension 45.12992 IN Pallet (8) - Customary Length Dimension 48 IN Pallet (8) - Customary Width Dimension 42 IN Pallet (8) - Metric Weight 185.972 KG Pallet (8) - Metric Net Weight 14.717 KG Pallet (8) - Metric Cubic Dimension 1490926.567 CCM Pallet (8) - Metric Height Dimension 114.63 CM Pallet (8) - Metric Length Dimension 121.92 CM Pallet (8) - Metric Width Dimension 106.68 CM Pallet (8) - Previous Packaging Level Quantity 63.00 Pallet (8) - Previous Packaging Level Unit BOX Pallet (8) - Item Quantity 630 Pallet (8) - Total Unit Quantity 630.00 Pallet (8) - Item Unit EACH Pallet (8) - Unit PAL Pallet (8) - Pallet Layer Quantity 7.00 Pallet (8) - Shipping Container Per Layer Quantity 9
